Model No.:-
O General Cassette Air conditioner is perfect selection for office or house where you have suspended ceiling. Cassette type will look nice in your interior, because the face panel only will showed. The benefit of cassette type that air distributing by four directions, what will provide proper cooling distribution around the room.
Model No. | Indoor/Outdoor units | AUGA18FRTA-U/AOGA18FBTBHU | AUGA25FRTA-U/AOG25FBTBHU | AUGA30FRTA-U/AOGA30FBTCSU | AUGA36FRTA-U/AOGA36FRTCSU | AUGA45FRTA-U/AOGA45FRTCSU | AUGA54FRTA-U/AOGA54FRTCSU |
Power Source | V/Ph/Hz | 240-220/1/50 | 240-220/1/50 | 240-220/1/50 | 415-380/3/50 | 415-380/3/50 | 415-380/3/50 |
Capacity class | BTU | 18000 | 25000 | 30000 | 36000 | 45000 | 54000 |
Input Power T3 condition | kW | 1.77 | 2.20 | 2.92 | 3.73 | 4.83 | 5.42 |
Current T3 condition | A | 7.8 | 9.9 | 13.2 | 6.0 | 7.8 | 8.8 |
Power Factor T3 condition | % | 98.7 | 96.6 | 96.2 | 89.7 | 89.4 | 88.9 |
EER T3 condition | Btu/hW | 9.60 | 8.95 | 8.73 | 8.42 | 7.40 | 7.42 |
Air Flow rate (high) | CFM | m3/h | 677 | 1150 | 677 | 1150 | 1006 | 1200 | 1177 | 2000 | 2136 | 2100 | 2136 | 2100 |
Net Dimention (indoor), Weight | HxWxD (mm) | kg | 246x840x840 | 24 | 246x840x840 | 24 | 288x840x840 | 26.5 | 288x840x840 | 29 | 288x840x840 | 29 | 288x840x840 | 29 |
Net Dimention (outdoor), Weight | HxWxD (mm) | kg | 650x830x320 | 50 | 830x900x330 | 63 | 914x970x370 | 77 | 1290x900x330 | 103 | 1290x900x330 | 102 | 1290x900x330 | 107 |
Refrigerant | R410A | R410A | R410A | R410A | R410A | R410A |
The warranty does not cover transportation outside the country. O General Window and Split Systems are covered for 12 months for the entire units and five years for the compressor from date of invoice. The warranty is applicable on original components only and against manufacturing defects, labor and consumables are excluded. Unit under warranty must be installed, maintained and operated as per manufacturer manuals.
To install a cassette air conditioner (cassette split system), as well as for a ducted air conditioner, a false ceiling is necessary. However, unlike channel split systems, cassette type air conditioners distribute the cooled air through the bottom of the unit. The cassette ac installation as well as wall mounted depends of main criteria as: pipe length, hight difference between indoor and outdoor units and available space to fit out cassette split ac
Maintenance of air conditioner should be providing on a regular base 2-3 times a year in UAE climate conditions. Standard ac maintenance work should include: